Min. 26 ga., 16" wide concealed fastener roof panel over min. 19/32" thick plywood deck
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
November 24, 2021
Validation Date:
November 29, 2021
HVHZ Approved:
No
Impact Resistant:
[ None ]
Design Pressures:
-139.1psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 71 00 - Roof Specialties
CSI Code: 07 41 23 - Wood Roof Panels
Other:
Uplift load of 84.3 psf @ fastener spacing of 24", 102.7 psf @ fastener spacing of 6" and 139.1 psf @ fastener spacing of 6" with 3/8" bead adhesive in sidelap
Notes:
Date Submitted: November 24, 2021
Date Validated: November 29, 2021
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 84.3 psf @ fastener spacing of 24", 102.7 psf @ fastener spacing of 6" and 139.1 psf @ fastener spacing of 6" with 3/8" bead adhesive in sidelap
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
David Stermer
Address: