FL7271.5-R5
Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:
MasterRib
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Min 29 ga., 36" wide through fastened panel over nom. 1" x 4" furring and 15/32" thick plywood or 7/16" thick OSB
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 10, 2020
Validation Date:
October 12, 2020
Design Pressures:
-114psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 41 63 - Fabricated Roof Panel Assemblies
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
Other:
Uplift load of 71 psf for Fastener Pattern 1 & 114 psf for Fastener Pattern 2
Notes:
Date Submitted: October 10, 2020
Date Validated: October 12, 2020
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 71 psf for Fastener Pattern 1 & 114 psf for Fastener Pattern 2
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Randy Blake
Address:
PO Box 229,
Fayetteville, North Carolina 28302 United States
Fayetteville, North Carolina 28302 United States
Phone:
Website:
Listing Changes
Last Synced: 07/25/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL7271 R5 II EVALUATIONREPORTC2400 5

PR TECH DOCS FL7271 R5 AE EVALUATIONREPORTC2400 5
QR Code To This Listing